Reference
Insulated metal panel and Division 07 glossary
Plain-language definitions of the insulated metal panel, rainscreen, and building-envelope terms architects meet when specifying CENTRIA systems.
- Insulated metal panel (IMP) (IMP)
- A factory-built wall or roof panel with two metal faces bonded to a foam-insulated core, so a single component carries the cladding, insulation, and the air, water, vapor, and thermal barrier.
- Barrier wall
- A wall in which the exterior face itself is the primary water, air, and vapor barrier, as with an insulated metal panel, rather than relying on a drained cavity behind a separate skin.
- Rainscreen
- A cladding approach where an outer skin is held off a separate backup wall, with a drained, back-ventilated cavity that manages water passing the face.
- Pressure-equalized rainscreen
- A rainscreen detailed so the cavity air pressure can equalize with the exterior, reducing the pressure difference that drives water through joints. Evaluated by AAMA 508.
- Continuous insulation (ci)
- Insulation that runs uninterrupted across the wall, not bridged by framing. Required in increasing amounts by the energy code and measured through assembly U-factor.
- Thermal bridging
- Heat flow through conductive paths such as studs, girts, clips, and fasteners that bypass the insulation and lower the real thermal performance of the wall.
- R-value
- A measure of a material's or assembly's resistance to heat flow. Higher is better. For insulated metal panels it rises with core thickness, roughly R-7 to R-8 per inch of PIR foam.
- U-factor
- The rate of heat transfer through an assembly, the inverse of R-value. Lower is better. Energy codes are often written as a maximum assembly U-factor.
- Polyisocyanurate (PIR)
- The rigid foam-plastic insulation poured in place as the core of most insulated metal panels, valued for its high R-value per inch.
- NFPA 285
- A fire-test standard for exterior wall assemblies containing combustible components, such as foam-plastic insulation. Compliance applies to the tested assembly, not a single product.
- ASTM E84
- The surface burning characteristics test (the Steiner tunnel), reporting flame-spread and smoke-developed indexes for a material.
- ASTM E119
- The standard fire-resistance test for building assemblies, reporting a fire-resistance rating in hours.
- ASTM E283
- The test for air leakage through an exterior wall assembly under a specified pressure difference.
- ASTM E331
- The test for water penetration of an exterior wall assembly under static pressure.
- ASTM E330
- The test for structural performance of an exterior wall assembly under uniform static air-pressure (wind) loads.
- AAMA 508
- The voluntary test and specification for pressure-equalized rainscreen wall systems, covering air, water, and structural performance of the assembly.
- Air barrier
- The material or system that controls air leakage through the building enclosure. In an insulated metal panel the sealed joints and panel skins form the air barrier.
- Vapor barrier
- A material that limits the diffusion of water vapor through the wall. The metal faces of an insulated metal panel act as vapor barriers.
- Concealed fastener
- An attachment method where clips and fasteners are hidden in the panel joint for a clean, unbroken face, as in FORMAWALL® and the CONCEPT SERIES.
- Exposed fastener
- An attachment method where fasteners are driven through the panel face, visible on the elevation. Economical and fast, as in STYLE-RIB and ECONOLAP.
- Reveal
- The recessed shadow line at a panel joint. Deeper reveals read as crisper, more articulated facades; FORMAWALL® offers a range of reveal depths.
- Standing seam
- A roof or wall panel joint where the seam stands up above the panel plane and is mechanically or snap seamed, shedding water and allowing thermal movement. Used by SDP200.
- Girt / subgirt
- Horizontal (girt) or secondary (subgirt) framing members that panels attach to and span between. Subgirts are often part of a rainscreen attachment.
- PVDF coating
- A high-performance fluoropolymer finish (commonly known by the Kynar resin) with excellent fade and chalk resistance and long warranty terms.
- FEVE coating
- A fluoroethylene vinyl ether finish offering high durability and higher-gloss options than standard PVDF, used for premium architectural finishes.
- Galvanized steel (G-90)
- Steel with a zinc coating for corrosion resistance; G-90 denotes a specific coating weight commonly used as the substrate for metal panels.
- Environmental Product Declaration (EPD)
- A third-party-verified document reporting the life-cycle environmental impacts of a product, used for LEED and embodied-carbon accounting.
- Health Product Declaration (HPD)
- A standardized disclosure of a product's material contents and associated health hazards, used in material-transparency credits.
- Declare label
- A material-ingredient label (a nutrition label for products) that discloses contents and Red List status, used in the Living Building Challenge and LEED.
- STC (STC)
- Sound Transmission Class, a single-number rating of how well an assembly reduces airborne sound. Higher blocks more sound.
- MasterFormat 07 42 13
- The CSI MasterFormat section for Metal Wall Panels; insulated metal wall panels are commonly specified under its 07 42 13.19 subsection.
Put a CENTRIA specialist on your project.
G&L Associates helps architects select the system, edit the specification, resolve the details, and budget the package, at no cost and with no login. Send drawings and we respond with real numbers.

