Energy & code 6 min read

Continuous insulation and the energy code

Why insulated metal panels are an efficient path to continuous insulation under the IECC and ASHRAE 90.1, and how to show compliance.

What continuous insulation means

Continuous insulation (ci) is insulation that runs uninterrupted across the wall, not broken by studs, girts, or other framing. Because framing conducts heat around cavity insulation, codes increasingly require a layer of continuous insulation and judge the wall by its whole-assembly U-factor rather than the center-of-cavity R-value.

What the codes require

The IECC and ASHRAE 90.1 set minimum envelope performance by climate zone, with prescriptive tables that list required continuous insulation for steel-framed and other wall types, or an equivalent maximum assembly U-factor. The exact figures depend on the adopted code edition and the climate zone, so size the wall to the specific requirement in force on your project.

Why insulated metal panels fit

In an insulated metal panel, the foam core is itself continuous insulation: it carries the insulation, the air and vapor barrier, and the cladding in one factory-built component, with no studs interrupting the thermal layer. That makes IMPs an efficient way to meet a ci requirement compared with a steel-stud wall that has to add an outboard insulation layer.

Mind the thermal bridges

The real assembly U-factor depends on the joints, fasteners, and transitions, not just the core. Specify thermally broken details at girts, clips, and penetrations, and use the manufacturer's published assembly U-factors rather than a bare core R-value. CENTRIA IMP assemblies publish U-factors that meet or exceed IECC requirements.

Showing compliance

You can comply by the prescriptive U-factor path, using the assembly U-factor from the panel data, or by a performance path such as COMcheck or whole-building energy modeling. Either way, the number that matters is the assembly U-factor, which G&L can pull from the current CENTRIA data for your thickness and configuration.

Frequently asked

Questions, answered.

Do insulated metal panels count as continuous insulation?

Yes. The foam core of an insulated metal panel is a continuous insulation layer uninterrupted by framing, which is why IMPs are an efficient way to meet an IECC or ASHRAE 90.1 continuous-insulation requirement.

How do I find the assembly U-factor for an IMP wall?

Use the manufacturer's published assembly U-factor for the specific panel, thickness, and configuration, rather than a center-of-core R-value. G&L can provide the current CENTRIA figures for your assembly.

Put a CENTRIA specialist on your project.

G&L Associates helps architects select the system, edit the specification, resolve the details, and budget the package, at no cost and with no login. Send drawings and we respond with real numbers.