Specifying 8 min read

How to specify insulated metal panels

A practical, manufacturer-neutral walk-through for writing an insulated metal panel into Division 07, from section numbers to the submittals worth requiring.

Where insulated metal panels sit in Division 07

Insulated metal wall panels are specified under MasterFormat Section 07 42 13 (Metal Wall Panels), most often as the subsection 07 42 13.19 for insulated metal wall panels. Insulated and structural metal roof panels fall under 07 41 13 (Metal Roof Panels). Composite backup panels that sit behind a rainscreen are also written in the 07 42 00 family.

Coordinate the panel section with the air barrier (07 27 00), joint sealants (07 92 00), and the glazing and flashing sections so the enclosure reads as one continuous system rather than a stack of unrelated products.

Specify performance, not just a product

The strongest IMP specs define measurable performance so any compliant product, and any substitution, has to clear the same bar. Call out thermal performance as an assembly U-factor or R-value, air and water and structural performance by test standard (ASTM E283, E331, and E330, or AAMA 508 for pressure-equalized rainscreen assemblies), fire performance (NFPA 285 for the wall assembly and ASTM E84 surface burning for the panel), structural capacity against the project wind loads, and acoustic STC where sound control matters.

Writing to standards keeps the specification open and defensible while still guaranteeing the enclosure performs.

Pin down thickness, profile, and orientation

Three choices shape most of the result. Core thickness sets the R-value and U-factor, so size it to the energy code for your climate zone (see our guide on core thickness and R-value). Profile sets the look, from a flat monolithic face to deep reveals. Orientation, horizontal or vertical, changes the joint, the water path, and the supporting steel (see horizontal vs vertical).

Decide these early, because they drive the structural layout and the detailing, not just the elevations.

Finishes, color, and warranty

Specify the coating system and the warranty term, not only a color. High-performance PVDF (commonly known by the Kynar resin) and FEVE coatings carry the longest fade and chalk warranties; metallics, prints, and custom colors are available at different warranty tiers. CENTRIA finishes span Fluorofinish and Fluorofinish Pure, Duragard, Sundance, Allura, Kolorshift, Impressions, and Celestial Effects.

State the required finish warranty (for example a 20 to 30 year film-integrity and fade warranty) so the color choice and the durability expectation travel together.

The details are the specification

An IMP performs only as well as its transitions. Require the manufacturer's standard details, and project-specific shop details, for the base, parapet, window head, jamb, and sill, inside and outside corners, and expansion joints, and show the air and vapor barrier continuity into adjacent assemblies. G&L produces this shop-level detailing as part of its design-assist.

Submittals worth requiring

Ask for product data and finish samples, shop drawings, structural calculations for the project loads, documentation of NFPA 285 compliance for a matching assembly or a qualified engineering judgment, and the finish and system warranties. These are the submittals that catch a non-compliant substitution before it reaches the wall.

A single accountable source

G&L Associates is a CENTRIA architectural metal systems specialist. We help select the system, provide an edited 3-part specification for your project, produce the shop details, budget the package, and coordinate it through construction. Send drawings for a material estimate or ask us to compare systems on performance.

Frequently asked

Questions, answered.

What MasterFormat section covers insulated metal panels?

Insulated metal wall panels are specified under Section 07 42 13 (Metal Wall Panels), commonly the 07 42 13.19 subsection for insulated metal wall panels. Insulated and structural metal roof panels fall under 07 41 13 (Metal Roof Panels).

Can G&L provide an edited 3-part specification?

Yes. G&L Associates provides project-specific, edited CENTRIA guide specifications along with shop-level details, so the written spec and the drawn details match the panel you are actually getting. Send us your drawings to start.

Put a CENTRIA specialist on your project.

G&L Associates helps architects select the system, edit the specification, resolve the details, and budget the package, at no cost and with no login. Send drawings and we respond with real numbers.