Energy & code 5 min read

Choosing insulated metal panel core thickness and R-value

Core thickness is the main lever on thermal performance. Here is how to size it to the code and the climate.

Thickness drives R-value

The poured-in-place polyisocyanurate (PIR) core in an insulated metal panel delivers roughly R-7 to R-8 per inch, so thickness is the main control on thermal performance. As a rule of thumb, a 2 inch panel lands near R-14 to R-16 and a 3 inch panel near R-21 to R-24, with U-factors to match. Treat these as planning ranges and confirm the exact value on the current CENTRIA data sheet for the panel and finish.

Match thickness to the energy code

Size the core so the assembly U-factor meets the IECC or ASHRAE 90.1 requirement for your climate zone. Colder zones call for thicker cores; milder zones may meet code at a thinner panel. Because the panel is continuous insulation, you are usually sizing one layer rather than stacking cavity plus outboard insulation.

Weigh the trade-offs

Thicker cores add R-value but also cost, weight, and sometimes joint or reveal detailing. Past the code minimum, returns diminish unless you are chasing a high-performance or LEED target, so match thickness to the performance goal rather than defaulting to the thickest panel.

CENTRIA thickness ranges

FORMAWALL® Dimension Series runs 2 to 3 inches. FORMAWALL® Graphix Series is offered at 2.5 inches (about R-20.1) and 3 inch-T (about R-24.1). VERSAWALL® is available in 2, 2.75, and 4 inch thicknesses. Compare the thermal figures side by side on the performance page.

Confirm on the data sheet

Published R-values and U-factors vary slightly by panel, thickness, and test basis, so the governing number for your submittal comes from the current CENTRIA data sheet. G&L confirms the assembly U-factor for your configuration and climate zone.

Frequently asked

Questions, answered.

What R-value does a 3 inch insulated metal panel have?

A 3 inch PIR-core panel is typically in the range of about R-21 to R-24, depending on the product and test basis. For example, FORMAWALL® Graphix Series at 3 inch-T is published near R-24.1. Confirm the exact figure on the current CENTRIA data sheet.

How thick should my insulated metal panels be?

Thick enough that the assembly U-factor meets the IECC or ASHRAE 90.1 requirement for your climate zone, then adjusted up only if you are targeting higher performance. G&L can size it to your code and confirm the number.

Put a CENTRIA specialist on your project.

G&L Associates helps architects select the system, edit the specification, resolve the details, and budget the package, at no cost and with no login. Send drawings and we respond with real numbers.