Performance & spec data

CENTRIA panel performance, side by side

Thermal, profile, and structural data for every CENTRIA system in one place, paraphrased from current CENTRIA literature. Figures are planning values; confirm the governing numbers for your assembly on the current CENTRIA data sheet, or ask G&L to pull them for your configuration.

Insulated metal panels

Thermal and construction

SystemCore thicknessThermal (approx.)Orientation
FORMAWALL® Dimension Series2" to 3"Up to R-8 per inch; U as low as 0.045Horizontal or vertical
FORMAWALL® Graphix Series2.5" and 3"-TR-20.1 (U 0.056) and R-24.1 (U 0.045)Horizontal or vertical
VERSAWALL®2", 2.75", 4"Thermal-broken; per CENTRIA data sheetHorizontal (H+) or vertical (V+)
VERSAPANEL®Per data sheetThermal-broken; per CENTRIA data sheetVertical; wall or roof
METALWRAP® SeriesPer data sheetAssembly U-factor meets or exceeds IECCHorizontal or vertical

All CENTRIA insulated metal panels use a poured-in-place PIR foam core (roughly R-7 to R-8 per inch) and form a continuous air, water, vapor, and thermal barrier. See core thickness and R-value for how to size the panel to the energy code.

Rainscreen & single-skin

Profile and material

SystemTypeDepthCoverageSubstrate
INTERCEPT®Modular rainscreen1-3/8" to 4" by schemeModular0.063" aluminum
CONCEPT SERIESConcealed-fastener rainscreen7/8"12" or 16"Steel or aluminum
STYLE-RIBExposed fastener1-1/2"36"24 to 18 ga steel; alum, SS
SUPER-RIBExposed fastener4"24"22 to 18 ga steel; alum
ECONOLAPExposed fastener3/4"34-2/3"24 to 18 ga steel; alum, SS
ECOSCREEN®Perforated screen7/8"12"20 ga SS, aluminum, or zinc

Single-skin and rainscreen profiles carry no insulation of their own. Over a METALWRAP® composite backup they become an insulated, barrier-backed rainscreen. See IMP vs rainscreen vs single-skin.

Roof systems

Roof panels

SystemTypeWidthSeam / jointLength
SDP200Structural standing-seam16" or 18"2" mechanically seamed9 to 38 ft; runs to 225 ft
VERSAPANEL® RoofInsulated metal roof panelPer data sheetSnap-on cap conceals jointPer data sheet
Fire, code & test standards

The standards to specify to

NFPA 285

Flame-propagation test for exterior wall assemblies with combustible components. CENTRIA insulated metal panels are tested extensively to it; compliance is per the assembly. Read the guide.

ASTM E283 / E331 / E330

Air leakage, water penetration, and structural (wind-load) performance of the wall assembly. Specify these so a substitution has to clear the same bar.

AAMA 508

The test and specification for pressure-equalized rainscreen systems, covering air, water, and structural performance. INTERCEPT® complies with AAMA 508.

ASTM E84

Surface burning characteristics (flame-spread and smoke-developed index) for the panel material. Pair it with NFPA 285 for the assembly.

Drawings & specifications

CAD, BIM, and 3-part specs

CENTRIA publishes CAD details, Revit and BIM content, data sheets, and editable 3-part guide specifications for every system. G&L edits the specification to your project and produces the shop-level details.

Put a CENTRIA specialist on your project.

G&L Associates helps architects select the system, edit the specification, resolve the details, and budget the package, at no cost and with no login. Send drawings and we respond with real numbers.