CENTRIA panel performance, side by side
Thermal, profile, and structural data for every CENTRIA system in one place, paraphrased from current CENTRIA literature. Figures are planning values; confirm the governing numbers for your assembly on the current CENTRIA data sheet, or ask G&L to pull them for your configuration.
Thermal and construction
| System | Core thickness | Thermal (approx.) | Orientation |
|---|---|---|---|
| FORMAWALL® Dimension Series | 2" to 3" | Up to R-8 per inch; U as low as 0.045 | Horizontal or vertical |
| FORMAWALL® Graphix Series | 2.5" and 3"-T | R-20.1 (U 0.056) and R-24.1 (U 0.045) | Horizontal or vertical |
| VERSAWALL® | 2", 2.75", 4" | Thermal-broken; per CENTRIA data sheet | Horizontal (H+) or vertical (V+) |
| VERSAPANEL® | Per data sheet | Thermal-broken; per CENTRIA data sheet | Vertical; wall or roof |
| METALWRAP® Series | Per data sheet | Assembly U-factor meets or exceeds IECC | Horizontal or vertical |
All CENTRIA insulated metal panels use a poured-in-place PIR foam core (roughly R-7 to R-8 per inch) and form a continuous air, water, vapor, and thermal barrier. See core thickness and R-value for how to size the panel to the energy code.
Profile and material
| System | Type | Depth | Coverage | Substrate |
|---|---|---|---|---|
| INTERCEPT® | Modular rainscreen | 1-3/8" to 4" by scheme | Modular | 0.063" aluminum |
| CONCEPT SERIES | Concealed-fastener rainscreen | 7/8" | 12" or 16" | Steel or aluminum |
| STYLE-RIB | Exposed fastener | 1-1/2" | 36" | 24 to 18 ga steel; alum, SS |
| SUPER-RIB | Exposed fastener | 4" | 24" | 22 to 18 ga steel; alum |
| ECONOLAP | Exposed fastener | 3/4" | 34-2/3" | 24 to 18 ga steel; alum, SS |
| ECOSCREEN® | Perforated screen | 7/8" | 12" | 20 ga SS, aluminum, or zinc |
Single-skin and rainscreen profiles carry no insulation of their own. Over a METALWRAP® composite backup they become an insulated, barrier-backed rainscreen. See IMP vs rainscreen vs single-skin.
Roof panels
| System | Type | Width | Seam / joint | Length |
|---|---|---|---|---|
| SDP200 | Structural standing-seam | 16" or 18" | 2" mechanically seamed | 9 to 38 ft; runs to 225 ft |
| VERSAPANEL® Roof | Insulated metal roof panel | Per data sheet | Snap-on cap conceals joint | Per data sheet |
The standards to specify to
NFPA 285
Flame-propagation test for exterior wall assemblies with combustible components. CENTRIA insulated metal panels are tested extensively to it; compliance is per the assembly. Read the guide.
ASTM E283 / E331 / E330
Air leakage, water penetration, and structural (wind-load) performance of the wall assembly. Specify these so a substitution has to clear the same bar.
AAMA 508
The test and specification for pressure-equalized rainscreen systems, covering air, water, and structural performance. INTERCEPT® complies with AAMA 508.
ASTM E84
Surface burning characteristics (flame-spread and smoke-developed index) for the panel material. Pair it with NFPA 285 for the assembly.
CAD, BIM, and 3-part specs
CENTRIA publishes CAD details, Revit and BIM content, data sheets, and editable 3-part guide specifications for every system. G&L edits the specification to your project and produces the shop-level details.
Put a CENTRIA specialist on your project.
G&L Associates helps architects select the system, edit the specification, resolve the details, and budget the package, at no cost and with no login. Send drawings and we respond with real numbers.